Europe’s heat-pump transition is not only changing compressors, controls and heating systems. It is changing the refrigerant inside the machine — and that changes what technicians need to know.
One refrigerant appearing increasingly in domestic heat pumps is R290: propane.
Its climate impact is exceptionally low compared with many fluorinated refrigerants. The European Commission lists R290 at a 100-year global warming potential (GWP100) of 0.02. For comparison, it lists R32 at 675 and R454C at 146.
But there is a trade-off that matters much more to the person holding the tools:
Propane is an A3 refrigerant — highly flammable.
That does not make an R290 heat pump inherently unsafe. It means that servicing one cannot simply be treated as the same job with a different bottle of refrigerant.
Why R290 is appearing now
The regulatory direction in Europe is clear.
Regulation (EU) 2024/573 progressively restricts equipment using fluorinated greenhouse gases.
One important deadline is approaching quickly. From 1 January 2027, self-contained air-conditioning equipment and heat pumps with rated capacity up to and including 12 kW face restrictions on fluorinated greenhouse gases with GWP of 150 or more, subject to the regulation’s safety provisions.
Split systems have their own timetable. Split air-to-water systems up to and including 12 kW using fluorinated greenhouse gases with GWP of 150 or more face a placing-on-the-market prohibition from 1 January 2027, again subject to the regulation’s safety exception.
That does not mean that every heat pump sold after 2027 must use propane.
CO₂ and other refrigerants remain possible, and the regulation contains different rules for different equipment categories and capacities.
But the direction explains why manufacturers have strong reasons to develop equipment around very-low-GWP refrigerants such as R290.
The part a technician cannot ignore
R290 is not simply “environmentally friendly refrigerant.”
It is propane.
The European Commission lists R290 in safety group A3, while R32 is A2L.
That changes the risk assessment around a refrigeration circuit.
With a flammable refrigerant, a leak is not only a refrigerant-loss problem. Under the wrong conditions, released refrigerant and an ignition source can create a fire or explosion hazard.
This is where shortcuts become dangerous.
The tools matter too
A technician should not assume that every tool previously used on an HFC system is automatically suitable for an A3 system.
Equipment used during installation, maintenance and repair has to be appropriate for the refrigerant and the task. The correct question is not:
“Can I connect this tool?”
It is:
“Is this tool approved and suitable for this refrigerant and this operation?”
Those are different questions.
And because equipment designs differ, a generic internet procedure should never override the heat-pump manufacturer’s service documentation.
Certification is changing as well
There is another important change that can easily be missed.
Commission Implementing Regulation (EU) 2024/2215 establishes minimum certification requirements for technicians working on relevant refrigeration, air-conditioning and heat-pump equipment. Its certificate categories now explicitly cover hydrocarbons as well as fluorinated greenhouse gases, and separate categories cover CO₂ and ammonia.
That is a significant change for the trade.
The transition away from high-GWP refrigerants does not reduce the need for trained refrigeration technicians.
In some respects, it increases it.
Standards are moving too
The equipment itself is covered by evolving safety standards.
IEC 60335-2-40 deals with safety requirements for electrical heat pumps, air conditioners and dehumidifiers. The 2024 edition is current, and IEC published Amendment 1 on 13 August 2026.
For someone in the workshop or on site, the lesson is simple:
Do not learn R290 from one refrigerant chart.
The refrigerant properties, equipment design, installation rules, manufacturer instructions, applicable standards and national certification requirements all belong to the job.
What changes in the real world
A modern R290 heat pump can arrive looking much like another outdoor heat-pump unit.
That visual familiarity is precisely why technicians need discipline.
Before working on the refrigerant circuit, the technician needs to know what refrigerant is present, understand its hazards, use suitable equipment and follow the manufacturer’s procedure and applicable safety requirements.
A mechanic would not treat a high-voltage EV battery like a 12-volt starter battery simply because both store electrical energy.
Refrigeration deserves the same thinking.
Different technology means different hazards.
Different hazards mean different procedures.
Where mistakes are likely to happen
The biggest risk may not be experienced refrigeration professionals who deliberately train for hydrocarbons.
It may be familiarity.
Someone who has spent years servicing R410A or R32 equipment can recognise the compressor, service connections, heat exchangers and refrigeration circuit. That can create the impression that the work is basically unchanged.
It is not.
R32 itself is classified differently from R290: R32 is A2L; R290 is A3.
The difference is not marketing language. It is part of the refrigerant’s safety classification.
The opportunity for the trade
There is another side to this transition.
Every technological change creates a period when knowledge becomes valuable.
Heat pumps still need commissioning.
They still need diagnosis.
Sensors fail. Pumps fail. Fans fail. Valves fail. Electrical connections develop faults. Controls need troubleshooting. Refrigeration circuits sometimes require qualified intervention.
A lower-GWP refrigerant does not eliminate skilled work.
It changes the skill set.
The technicians who understand both the refrigeration cycle and the safety requirements of the new refrigerants will be more useful than technicians who simply know how to connect gauges.
That is the part of the energy transition that rarely makes the headline.
The machine changes.
The trade has to change with it.
References and original documents
This is an independent explanation, not a hands-on test or endorsement.
- European Commission — Climate-friendly alternatives to F-gases: Air conditioning and heat pumps — Official EU refrigerant data and safety classifications, including R290, R32 and R454C.
- EUR-Lex — Regulation (EU) 2024/573 on fluorinated greenhouse gases — Primary EU legal text; Annex IV contains placing-on-the-market restrictions for heat pumps and air-conditioning equipment.
- EUR-Lex — Commission Implementing Regulation (EU) 2024/2215 — Primary EU legal text establishing minimum technician certification requirements, including hydrocarbons, CO2 and ammonia.
- IEC — IEC 60335-2-40:2024 — International safety standard for electrical heat pumps, air-conditioners and dehumidifiers.
- IEC — IEC 60335-2-40:2024/AMD1:2026 — Amendment 1, published 13 August 2026.
- University of Innsbruck / Applied Thermal Engineering — façade-integrated R290 mini-split heat pump — Real research prototype using propane (R290); the image is credited to the University of Innsbruck / Applied Thermal Engineering under CC BY 4.0.
This article is informational, not a servicing procedure. Work on equipment containing flammable refrigerants must follow the equipment manufacturer’s instructions, applicable standards, local law and the certification requirements for the work being performed.